01
/ 05
Place indicator in the pack.
Internal chemical indicator goes in the center of the most challenging pack. External indicator tape seals the outside of every wrapped pack.
Key Features
01
ISO 11140-classified indicators from simple process indicators (Class 1) to integrating indicators (Class 5) that react to all critical parameters.
02
Geobacillus stearothermophilus spore vials confirm true sterilization efficacy — the gold standard required weekly per AAMI ST79.
03
Peel pouches and CSR wraps maintain sterility through storage and transport. Integrated external indicator changes color after successful processing.
04
Lot-numbered indicators and load stickers support sterile-load tracking for regulatory audit and patient-instrument linkage.
Clinical Use / Sterilization Supplies
Sterilization indicators and packaging validate and protect the sterility of reprocessed instruments. Chemical indicators (Class 1–6) confirm exposure to sterilization parameters; biological indicators confirm spore kill. Every load requires both.
Indications
Application Technique
01
/ 05
Internal chemical indicator goes in the center of the most challenging pack. External indicator tape seals the outside of every wrapped pack.
02
/ 05
Place a biological indicator in the most challenging load location weekly (minimum) and in every implant load. Incubate per manufacturer IFU (24–48 hrs typically).
03
/ 05
Log chemical indicator color change, biological incubation result, cycle parameters, and load contents. Retain records per facility/state regulation (often 3–7 years).
04
/ 05
Event-related shelf life: sterile until packaging compromised. Store in closed cabinets, 18 inches below ceiling and 8–10 inches from floor.
05
/ 05
Implantable devices require a passed biological indicator before release — no exceptions. Hold implant loads until BI reads negative.
Contraindications & Cautions
Typical Care Settings
Clinical use information is provided for reference only. Always follow facility protocols, manufacturer instructions for use (IFU), and evidence-based practice guidelines. Consult the treating clinician before use.
Regulatory & Quality
Standards & Certifications
How It Compares
A spec-by-spec comparison with the most common alternatives in the sterilization supplies category. Clinical interchangeability varies — always verify with your care team or facility protocol.
| Spec | This product TABLET, AUTOCLAVE CLEAN & SHINE F/T-EDGE CHAMBER (12/BX) | Tuttnauer USA Chamber Brite Autoclave Cleaner, 1 Case of 120 | Tuttnauer USA Chamber Brite Autoclave Cleaner, 1 Each | Tuttnauer USA Tuttnauer Autoclave Door Gasket, 1 Each |
|---|---|---|---|---|
| Single-Use | Single-use | Single-use | Single-use | Single-use |
Comparison is provided for reference only. Brand names and trademarks belong to their respective owners. Specific SKUs may differ from category averages shown above.
Pairs With
Products commonly used alongside this one. Bundle them into a single order.

Tuttnauer USA
Clean & Simple Ultrasonic / Enzymatic Solution, 1 Box of 144
$148.84USD

Tuttnauer USA
Clean & Simple Ultrasonic / Enzymatic Solution, 1 Case of 1728
$1,564.43USD

The Clorox Company
Clorox® Healthcare® Surface Disinfectant Cleaner, 1 Case of 2
$86.04USD

Lagasse
Oxivir® Tb Surface Disinfectant Wipes, 1 Carton of 160
$32.98USD

Integra Lifesciences
Miltex® Instrument Lubricant, 1 Each
$27.67USD

Sklar
Sklar Kleen™ Instrument Detergent, 1 Each
$59.85USD
About the Brand
Trusted manufacturer
An established medical products manufacturer supplying clinical teams with quality healthcare supplies.
FAQ / Sterilization Supplies
Answers to the questions clinical buyers and care teams ask most about this product category.
Chemical indicators react to one or more sterilization parameters (time, temperature, pressure, steam presence) — they confirm the cycle ran, not that sterilization was achieved. Biological indicators contain resistant bacterial spores (G. stearothermophilus) that only die under true sterilization conditions — they confirm actual microbial kill.
AAMI ST79 requires a BI at least weekly, in every implantable load, and after any major maintenance. Many facilities run BIs daily or with every load for extra safety margin.
Class 5 indicators react to all critical sterilization parameters (time, temperature, and steam quality) and closely correlate with BI performance. They allow some release decisions when combined with other quality measures.
No. Sterilization pouches are single-use. The sealing and barrier layers are compromised after one cycle, and reprocessing voids the sterility assurance level.
Most modern guidance is event-related — packs stay sterile until the packaging is compromised (torn, wet, dropped). Time-dated shelf life (e.g., 30 days) may still apply per facility policy.
Related

O&M Halyard Inc
Sterilization Tray Liner Towel, 20 X 25 Inch, 1 Pack of 50
$30.42USD

Tuttnauer USA
Tuttnauer USA Recording Chart Paper, 1 Box of 5
$52.55USD

Healthmark Industries
Sterimarker Marker, 1 Box of 10
$68.19USD

SPS Medical Supply
PassPort® Sterilizer Monitoring Service, 1 Box of 12
$188.73USD

Tuttnauer USA
Tuttnauer Autoclave Door Gasket, 1 Each
$71.97USD

Aesculap
Aesculap Tamper Proof Lock, 1 Box of 1000
$394.13USD

V. Mueller
Genesis™ Sterilization Filter, 1 Box of 1000
$200.88USD

Tuttnauer USA
Chamber Brite Autoclave Cleaner, 1 Case of 120
$902.78USD
Tuttnauer USA
$111.73USD
$113.79USD
In Stock
Ships from our western US warehouses
Fast Shipping
Same-day processing before 2pm PST
30-Day Returns
Hassle-free on eligible orders
HSA / FSA
Eligible for most medical accounts
At a Glance
About this product
Tuttnauer® Autoclave Chamber Cleaner
Specifications
Product
Pricing
$111.73USD
$113.79USD
Inventory
Collections