01
/ 05
Assess pressure injury risk.
Use Braden or Norton scale to determine risk level. Match the support surface to the assessed risk category (Group 1, 2, or 3).
Key Features
01
Clinically proven to reduce peak pressure under bony prominences for patients at high risk of skin breakdown.
02
Cyclical air cell inflation redistributes pressure across the body surface without manual repositioning.
03
Continuous airflow manages moisture and temperature at the skin interface to reduce maceration.
04
Support surfaces qualify under Medicare Groups 1, 2, or 3 with appropriate documentation (E0180–E0277).
Clinical Use / Pressure Relief Mattresses
Alternating pressure, low-air-loss, and static overlay mattress systems for pressure injury prevention and treatment across all stages and care settings.
Indications
Application Technique
01
/ 05
Use Braden or Norton scale to determine risk level. Match the support surface to the assessed risk category (Group 1, 2, or 3).
02
/ 05
Static overlays for Group 1 prevention. Alternating pressure for Group 2 active prevention. Low-air-loss for Group 3 wound healing.
03
/ 05
Verify pump inflation, cycle time, and alarm settings per manufacturer IFU. Do not over-inflate or under-inflate cells.
04
/ 05
Continue scheduled skin inspection and repositioning per facility protocol. Mattress therapy augments but does not replace repositioning.
05
/ 05
Record surface type, settings, skin condition, and patient tolerance in the medical record.
Contraindications & Cautions
Typical Care Settings
Clinical use information is provided for reference only. Always follow facility protocols, manufacturer instructions for use (IFU), and evidence-based practice guidelines. Consult the treating clinician before use.
Regulatory & Quality
Standards & Certifications
How It Compares
A spec-by-spec comparison with the most common alternatives in the pressure relief mattresses category. Clinical interchangeability varies — always verify with your care team or facility protocol.
| Spec | This product Power-Pro Elite Bariatric Low Air Loss System 36 x 80 | Alternating pressure overlay Drive Med-Aire Plus APP | Hospital-grade LAL Arjo Atmos Plus Low-Air-Loss |
|---|---|---|---|
| Therapy Type | — | Alternating pressure | Low-air-loss + alternating |
| HCPCS Group | E0277 | Group 2 (E0277) | Group 2–3 |
| Weight Capacity | — | 300 lb | 400 lb |
| Pump Required | — | Included pump | Included pump |
| Low-Air-Loss | — | No | Yes |
| Alarm Package | — | Low-pressure alarm | Full alarm suite |
Comparison is provided for reference only. Brand names and trademarks belong to their respective owners. Specific SKUs may differ from category averages shown above.
Product Family
Other sizes, pack counts, and variants of the same product line.
Pairs With
Products commonly used alongside this one. Bundle them into a single order.

Unilever
Dove® Antiperspirant / Deodorant, 1 Each
$22.19USD

Hartmann
MoliCare® Positioning Underpad, 30 x 36 Inch, 1 Bag of 5
$33.28USD

Neutrogena
Neutrogena® Moisturizer, 1 Each
$24.14USD

3M
3M Cavilon Rinse-Free Body Wash, 8 Oz Pump Bottle, Floral Scent, 1 Each
$18.36USD

Cardinal
Cardinal Unscented Personal Wipe, 1 Pack of 96
$32.62USD

Dynarex
Dynarex Zinc Oxide Skin Protectant, Scented, 2 Oz Tube, 1 Case of 72
$180.23USD
About the Brand
Trusted manufacturer
An established medical products manufacturer supplying clinical teams with quality healthcare supplies.
FAQ / Pressure Relief Mattresses
Answers to the questions clinical buyers and care teams ask most about this product category.
Alternating pressure (APP) inflates and deflates air cells in cycles to redistribute pressure. Low-air-loss (LAL) provides continuous airflow through microperforated cells to manage skin moisture and temperature. Some systems combine both therapies.
Group 1: pressure-reducing overlay/mattress for prevention. Group 2: powered alternating or low-air-loss for Stage II+ injuries. Group 3: air-fluidized for severe Stage III–IV injuries and flap surgery. Documentation and medical necessity determine eligibility.
No. Even the highest-specification mattress is an adjunct to — not a replacement for — scheduled repositioning, skin inspection, and nutrition. Follow your facility's pressure injury prevention protocol.
Inspect daily for leaks, pump function, and alarm readiness. Most rental surfaces are maintained by the supplier; owned surfaces should be serviced per manufacturer schedule. Replace immediately if air cells are damaged.
Keep Reading
Related

Hospital Supply HQ
Power-Turn Elite Lateral Rotation w/Low Air Loss
$8,499.01USD

Hospital Supply HQ
Power-Pro Elite Bariatric Low Air Loss System 48 x 80
$7,258.59USD

Hospital Supply HQ
Rapid-Air Plus Air Loss & APP System
$2,001.03USD

Hospital Supply HQ
Power-Pro Elite Bariatric Low Air Loss System 42 x 80'
$6,699.18USD

Hospital Supply HQ
Alpha Active Top Sheet Cover Only
$1,065.08USD

Hospital Supply HQ
Cover Only for Low Air Loss Mattress 8
$215.40USD

Hospital Supply HQ
Supreme-Air Alternating Air Flotation Mattress System
$2,783.15USD

Hospital Supply HQ
Apollo 3-Port Low Air Loss Mattress & APP System
$2,149.50USD
Hospital Supply HQ
$6,139.74USD
$6,178.38USD
In Stock
Ships from our western US warehouses
Fast Shipping
Same-day processing before 2pm PST
30-Day Returns
Hassle-free on eligible orders
HSA / FSA
Eligible for most medical accounts
At a Glance
About this product
Specifications
Product
Pricing
$6,139.74USD
$6,178.38USD
Inventory
Collections