Medicom Safeseal® Quattro Sterilization Pouch, 7½" x 13", 1 Box of 200

About this item

Medicom® Safeseal® Quattro Sterilization Pouch, Film, Blue, Self-Seal Closure, 13 in Length, 7-1/2 in Width

    Specifications

    Brand
    Medicom, Inc.
    Category
    Sterilization Packaging
    Pack
    200 per case
    Per Unit
    $0.30
    MFR#
    88030-4
    GTIN
    10686864045806

    Built to the spec
    clinicians trust.

    Class 1–6 Chemical Indicators

    ISO 11140-classified indicators from simple process indicators (Class 1) to integrating indicators (Class 5) that react to all critical parameters.

    Biological Indicator Standard

    Geobacillus stearothermophilus spore vials confirm true sterilization efficacy — the gold standard required weekly per AAMI ST79.

    Sealable Pouches & Wraps

    Peel pouches and CSR wraps maintain sterility through storage and transport. Integrated external indicator changes color after successful processing.

    Traceability

    Lot-numbered indicators and load stickers support sterile-load tracking for regulatory audit and patient-instrument linkage.

    FDA
    Class II (21 CFR 880.2800 sterilization indicator)
    Latex
    Latex-free
    Sterility
    Non-sterile (indicators are consumables used in sterilization)
    Biocompatibility
    ISO 10993 where applicable

    Standards & Certifications

    • FDA 510(k) Cleared
    • ISO 11140-1 (chemical indicator classification)
    • ISO 11138 (biological indicators)
    • AAMI ST79 (steam sterilization and sterility assurance)

    More from Medicom, Inc.

    Trusted manufacturer

    An established medical products manufacturer supplying clinical teams with quality healthcare supplies.

    Frequently asked.

    Answers to the questions clinical buyers and care teams ask most about this product category.

    What's the difference between chemical and biological indicators?

    Chemical indicators react to one or more sterilization parameters (time, temperature, pressure, steam presence) — they confirm the cycle ran, not that sterilization was achieved. Biological indicators contain resistant bacterial spores (G. stearothermophilus) that only die under true sterilization conditions — they confirm actual microbial kill.

    How often do I need to run a biological indicator?

    AAMI ST79 requires a BI at least weekly, in every implantable load, and after any major maintenance. Many facilities run BIs daily or with every load for extra safety margin.

    What's a Class 5 integrating indicator?

    Class 5 indicators react to all critical sterilization parameters (time, temperature, and steam quality) and closely correlate with BI performance. They allow some release decisions when combined with other quality measures.

    Can sterilization pouches be reused?

    No. Sterilization pouches are single-use. The sealing and barrier layers are compromised after one cycle, and reprocessing voids the sterility assurance level.

    How long are sterile packs good for after processing?

    Most modern guidance is event-related — packs stay sterile until the packaging is compromised (torn, wet, dropped). Time-dated shelf life (e.g., 30 days) may still apply per facility policy.