About this item

  • Product features include final read-out in only 24 hours and fits existing incubators
  • Vials monitor steam sterilization processes
  • 100 vials per box

Specifications

Brand
McKesson Brand
Category
Sterilization Indicators
Pack
100 per case
Per Unit
$1.99
MFR#
73-SCS100
GTIN
20612479159154
Weight
0.249 lb

Built to the spec
clinicians trust.

Class 1–6 Chemical Indicators

ISO 11140-classified indicators from simple process indicators (Class 1) to integrating indicators (Class 5) that react to all critical parameters.

Biological Indicator Standard

Geobacillus stearothermophilus spore vials confirm true sterilization efficacy — the gold standard required weekly per AAMI ST79.

Sealable Pouches & Wraps

Peel pouches and CSR wraps maintain sterility through storage and transport. Integrated external indicator changes color after successful processing.

Traceability

Lot-numbered indicators and load stickers support sterile-load tracking for regulatory audit and patient-instrument linkage.

FDA
Class II (21 CFR 880.2800 sterilization indicator)
Latex
Latex-free
Sterility
Non-sterile (indicators are consumables used in sterilization)
Biocompatibility
ISO 10993 where applicable

Standards & Certifications

  • FDA 510(k) Cleared
  • ISO 11140-1 (chemical indicator classification)
  • ISO 11138 (biological indicators)
  • AAMI ST79 (steam sterilization and sterility assurance)

More from McKesson Brand

Trusted manufacturer

An established medical products manufacturer supplying clinical teams with quality healthcare supplies.

Frequently asked.

Answers to the questions clinical buyers and care teams ask most about this product category.

What's the difference between chemical and biological indicators?

Chemical indicators react to one or more sterilization parameters (time, temperature, pressure, steam presence) — they confirm the cycle ran, not that sterilization was achieved. Biological indicators contain resistant bacterial spores (G. stearothermophilus) that only die under true sterilization conditions — they confirm actual microbial kill.

How often do I need to run a biological indicator?

AAMI ST79 requires a BI at least weekly, in every implantable load, and after any major maintenance. Many facilities run BIs daily or with every load for extra safety margin.

What's a Class 5 integrating indicator?

Class 5 indicators react to all critical sterilization parameters (time, temperature, and steam quality) and closely correlate with BI performance. They allow some release decisions when combined with other quality measures.

Can sterilization pouches be reused?

No. Sterilization pouches are single-use. The sealing and barrier layers are compromised after one cycle, and reprocessing voids the sterility assurance level.

How long are sterile packs good for after processing?

Most modern guidance is event-related — packs stay sterile until the packaging is compromised (torn, wet, dropped). Time-dated shelf life (e.g., 30 days) may still apply per facility policy.