Gammex® Non-Latex Polyisoprene Surgical Glove, Size 6, Green, 1 Case of 200 () - Img 1

About this item

  • Having passed the mouse embryo assay (MEA) test, Gammex Non-Latex surgical gloves be used for in vitro fertilization (IVF) procedures
  • Ansell's proprietary soft yet strong formulation delivers heightened comfort and hand protection when double gloving An internal coating enables easy donning and doffing under dry or damp hand conditions Protection from chemical accelerators such as thiurams, carbamates and mercaptans known to cause chemical Type IV allergies
  • Size 6 is equivalent to extra-small: Extra small fits those whose palm circumference is between 5½ and 6 inches

Specifications

Brand
Ansell
Category
Surgical Gloves
Pack
200 per case
Per Unit
$3.16
MFR#
8512
Weight
9.344 lb

Built to the spec
clinicians trust.

Puncture & Tear Resistance

Nitrile and surgical-grade formulations resist pinholes and tears during high-dexterity procedural and suturing work.

Latex-Free Safety

Nitrile and vinyl gloves eliminate latex allergy risk for staff and patients. Material is clearly labeled on every box.

Tactile Sensitivity

Textured fingertips and thin-gauge construction preserve touch and grip for suturing, palpation, and instrument handling.

AQL-Rated Barrier

Acceptable Quality Level ratings define pinhole tolerance. Exam gloves meet AQL ≤2.5; surgical gloves meet the stricter AQL ≤1.5.

FDA
Class I (exam, 21 CFR 880.6250) / Class II (surgical, 21 CFR 878.4460)
Latex
Nitrile and vinyl: latex-free. Latex variants clearly labeled.
Sterility
Sterile (surgical) and non-sterile (exam) options
Biocompatibility
ASTM biocompatibility tested; chemo-rated options available

Standards & Certifications

  • FDA 510(k) Cleared
  • ASTM D6319 (nitrile exam)
  • ASTM D3578 (latex exam)
  • ASTM D5250 (vinyl exam)
  • ASTM D6978 (chemotherapy permeation)

More from Ansell

Trusted manufacturer

An established medical products manufacturer supplying clinical teams with quality healthcare supplies.

Frequently asked.

Answers to the questions clinical buyers and care teams ask most about this product category.

What's the difference between nitrile, vinyl, and latex gloves?

Nitrile is the clinical default — latex-free, puncture-resistant, and chemically durable. Vinyl is lower-cost with less barrier protection and looser fit; appropriate for short, low-risk tasks. Latex has excellent fit and tactile feedback but poses allergy risk and is being phased out of most facilities.

What does AQL mean on a glove box?

Acceptable Quality Level is the maximum percentage of gloves in a batch allowed to have pinholes or defects. Exam gloves are rated AQL ≤2.5; surgical gloves meet a stricter AQL ≤1.5. Lower AQL means tighter quality control and fewer barrier failures.

Are these chemo-tested?

Chemotherapy-tested gloves are specifically evaluated for permeation resistance against hazardous drugs under ASTM D6978. Always check the product label — not every nitrile glove is chemo-rated, and pharmacy compounding protocols require the ASTM D6978 mark.

Do these need to be sterile?

Exam gloves are non-sterile and appropriate for routine patient contact, standard precautions, and most procedural work. Sterile gloves are required for surgical procedures, central line placement, and any procedure entering a sterile body cavity.

How do I choose the right size?

Measure hand circumference across the widest part of the palm (excluding thumb). Map to XS (<7"), S (7–7.5"), M (7.5–8"), L (8–9"), XL (>9"). Too-tight gloves fatigue the hand and tear; too-loose gloves lose tactile sensitivity.