About this item

Medegen Medical Products Bio-Hazard Spill Kit, 6 Piece

    Specifications

    Brand
    Medegen Medical Products, Llc
    Category
    Fluid Management
    MFR#
    3000

    Built to the spec
    clinicians trust.

    Closed-System Fluid Path

    Luer-lock connections, slide clamps, and anti-kink tubing maintain patent fluid paths through long infusions and transport.

    Suction Containment

    Sealed liners capture fluid waste safely — float shut-offs prevent overflow and aerosol escape back into the vacuum line.

    Acoustic and Conductive Performance

    Ultrasound gels match tissue acoustic impedance for image clarity; ECG gels maintain low-impedance electrode contact.

    Clinically Standard Connectors

    Luer, ISO 80369 (enteral safety connectors), and universal suction fittings match facility infrastructure — no adapter gymnastics.

    FDA
    Class II (21 CFR 880.5440 IV set; 878.4730 suction canister)
    Latex
    Latex-free (modern clinical consumables)
    Sterility
    Sterile (IV and suction) / Non-sterile (gels)
    Biocompatibility
    ISO 10993 fluid-path tested

    Standards & Certifications

    • FDA 510(k) Cleared
    • ISO 80369 (small-bore connectors)
    • AAMI ST79 (reprocessing)
    • USP Class VI (fluid-path polymers)

    More from Medegen Medical Products, Llc

    Trusted manufacturer

    An established medical products manufacturer supplying clinical teams with quality healthcare supplies.

    Frequently asked.

    Answers to the questions clinical buyers and care teams ask most about this product category.

    Are these IV tubing sets compatible with my pumps?

    IV tubing compatibility is pump-specific. Most gravity sets are universal; pump-set cassettes are pump- and model-matched (Alaris, Baxter, Hospira, etc.). Verify set compatibility with your pump model.

    What suction pressure should I use for airway suctioning?

    Adult wall suction for airway: 80–120 mmHg. Pediatric: 60–100 mmHg. Neonatal: 60–80 mmHg. Higher pressures cause mucosal trauma and hypoxia. Always set to the lowest effective pressure.

    What's the difference between ECG and ultrasound gel?

    ECG gel is conductive and low-impedance to carry electrical signal between skin and electrode. Ultrasound gel is acoustic — matched to tissue impedance to transmit sound waves. They are not interchangeable.

    Can I empty suction canisters down the drain?

    No. Suction contents are biohazardous regulated medical waste. Use a disposable liner system or a closed-solidifier system for emptying — never pour to drain or to unprotected waste.

    Do you carry ISO 80369 enteral safety connectors?

    Yes — ISO 80369-3 (ENFit) enteral connectors prevent misconnection between feeding and IV lines. This is the standard for new enteral equipment and is required by many health systems.