01
/ 05
Label at collection.
Label specimen containers at the patient's bedside, at the moment of collection, and in the patient's presence. Never pre-label.
Key Features
01
Barcode and pre-printed labels enable closed-loop specimen identification from collection through result reporting — reducing mislabel and wrong-patient errors.
02
Cryo-rated, autoclave-rated, and solvent-resistant label stocks survive freezer (-80°C to -196°C liquid nitrogen), steam sterilization, and organic solvent exposure without peeling.
03
Standard microtube, cryovial, and pipette-tip formats are compatible with common lab automation and manual workflow.
04
Pipette tips and calibration accessories carry lot and certificate-of-compliance documentation for audit trail and QA.
Clinical Use / Laboratory Accessories & Labels
Clinical laboratory accessories and identification labels support specimen handling, sample traceability, and workflow accuracy in clinical, pathology, and research labs. Labels must survive sample-handling conditions (freezer, solvent, autoclave) without degrading.
Indications
Application Technique
01
/ 05
Label specimen containers at the patient's bedside, at the moment of collection, and in the patient's presence. Never pre-label.
02
/ 05
Joint Commission requires two patient identifiers on every specimen label — typically full name and date of birth or MRN.
03
/ 05
Cryo samples need cryo-rated labels. Autoclaved samples need autoclave-rated labels. Room-temperature samples tolerate standard paper labels.
04
/ 05
Match rack format to tube diameter and pipette tips to pipettor brand. Off-spec tips alter volume accuracy.
05
/ 05
Lab policy must reject specimens without two identifiers. Do not correct labels after the fact — recollect if identifiers are missing.
Contraindications & Cautions
Typical Care Settings
Clinical use information is provided for reference only. Always follow facility protocols, manufacturer instructions for use (IFU), and evidence-based practice guidelines. Consult the treating clinician before use.
Regulatory & Quality
Standards & Certifications
How It Compares
A spec-by-spec comparison with the most common alternatives in the laboratory accessories & labels category. Clinical interchangeability varies — always verify with your care team or facility protocol.
| Spec | This product BD Veritor™ System Control Swab Set for BD Veritor™ System Reader and Flu A+B Test, 1 Each | Globe Scientific Globe Scientific Test Tube Cap, 1 Case of 1000 | Advanced Medical Systems ENVIRO TEST MEDIA PADDLE | United Products & Instruments United Products & Instruments Microhematocrit Reader, 1 Each |
|---|---|---|---|---|
| Single-Use | Single-use | Single-use | Single-use | Single-use |
| Pack Size | — | 1000 per case | — | — |
Comparison is provided for reference only. Brand names and trademarks belong to their respective owners. Specific SKUs may differ from category averages shown above.
Pairs With
Products commonly used alongside this one. Bundle them into a single order.

BD
BD™ Universal Viral Transport Kit, 1 Pack of 50
$340.34USD

BD
BD Vacutainer® Urine Specimen Collection Kit, 1 Case of 50
$167.27USD

BD
BD™ Universal Viral Transport, 1 Pack of 50
$232.00USD

BD
BBL™ CultureSwab™ Swab Stick, 1 Each
$14.93USD

BD
TUBE, BLD COL LIHEP GRN 10ML PLAS VACUTAINER (100/BX 10BX/CS
$735.54USD

BD
eSwab Specimen Collection and Transport System, 1 mL, 1 Box of 50
$115.83USD
About the Brand
Trusted manufacturer
An established medical products manufacturer supplying clinical teams with quality healthcare supplies.
FAQ / Laboratory Accessories & Labels
Answers to the questions clinical buyers and care teams ask most about this product category.
Only cryo-rated labels survive -80°C or liquid-nitrogen (-196°C) storage. Standard paper labels peel and fall off at cryogenic temperatures. Verify the label's temperature rating before use.
No. Pipette tips are brand- and model-specific. Eppendorf, Rainin, Gilson, and generic universal fits have different shapes and volumes. Using off-spec tips alters pipetted volume accuracy.
Two patient identifiers (typically full name and DOB or MRN), specimen type, collection date/time, and collector initials are standard. Joint Commission requires two identifiers as a National Patient Safety Goal.
Slides require xylene- and solvent-resistant labels (often printed directly onto frosted slide ends). Standard paper labels dissolve during histology processing.
Use barcoded labels with closed-loop specimen collection systems. Integrate the barcode scan at every handoff (collection, transport, receipt, analyzer) to catch mislabels early.
Keep Reading
Related

Smiths Medical
Jelco® Needle-Pro® Needle Protection Device, 1 Case of 1000
$299.08USD

Cardinal
CUP, SAMPLE 1ML F/13MM TUBES 1.0ML (1000/PK 5PK/CS)
$52.11USD

Cardinal
Devon™ Surgi-Mark™ Surgical Utility Marker, Regular Tip, Sterile, 1 Box of 25
$64.40USD

Cardinal
Devon™ Surgi-Mark™ Surgical Utility Marker, Regular Tip, Sterile, 1 Each
$16.30USD

Greiner Bio-One
Vacuette® Standard Tube Holder, 1 Box of 100
$19.99USD

Smiths Medical
Jelco® Needle-Pro® Needle Protection Device, 1 Bag of 500
$153.93USD

Coagusense
SCANNER, BARCODE PT2 WIRELESS
$152.39USD

Cardinal
Devon™ Surgi-Mark™ Surgical Utility Marker, Regular Tip, Sterile, 1 Case of 100
$231.26USD
BD
$98.48USD
$110.72USD
In Stock
Ships from our western US warehouses
Fast Shipping
Same-day processing before 2pm PST
30-Day Returns
Hassle-free on eligible orders
HSA / FSA
Eligible for most medical accounts
At a Glance
About this product
Half of the swabs are for flu B positive and flu A negative control; the other half is for flu A positive and flu B negative control.
Specifications
Product
Pricing
$98.48USD
$110.72USD
Inventory
Collections
Clinical Evidence
01
/ 02
Infection Control & Hospital Epidemiology
National surveillance data analysis of needlestick injuries before and after safety device implementation.
Key Findings
Sample Size
450+ hospitals, 10-year data
02
/ 02
Journal of Vascular Access
Randomized trial comparing IV catheter securement devices on complication rates and dwell time.
Key Findings
Sample Size
1,108 patients
Regulatory Approvals
Referenced In
Learn More
View All Clinical Resources →Clinical evidence is provided for informational purposes only. Healthcare professionals should evaluate products based on their clinical judgment and patient-specific factors. Links to external studies are provided as references and do not constitute endorsement. Always refer to the manufacturer's instructions for use.