About this item

  • Moving front ink technology with vibrant "Accept" (Green) and "Reject" (Red) zones for easy interpretation within seconds
  • 3M Attest steam chemical integrators are used for pack control monitoring compliant with ISO 11140-1: 2014. Please review the instructions for use for applicable cycles in the U.S.
  • The integrator is designed to correlate with the performance of a biological indicator at three time/temperature relationships
  • White/red colored back: Makes the chemical integrator easy to find if/when it flips over within a surgical tray (Category 5) Integrating Indicators
  • 2-year shelf life
  • Strips are 2 inches long

Specifications

Brand
3M
Category
Sterilization Indicators
Pack
1000 per case
Per Unit
$0.21
MFR#
1243B
GTIN
50707387785746
Weight
0.721 lb

Also available in.

Other sizes, pack counts, and variants of the same product line.

Built to the spec
clinicians trust.

Class 1–6 Chemical Indicators

ISO 11140-classified indicators from simple process indicators (Class 1) to integrating indicators (Class 5) that react to all critical parameters.

Biological Indicator Standard

Geobacillus stearothermophilus spore vials confirm true sterilization efficacy — the gold standard required weekly per AAMI ST79.

Sealable Pouches & Wraps

Peel pouches and CSR wraps maintain sterility through storage and transport. Integrated external indicator changes color after successful processing.

Traceability

Lot-numbered indicators and load stickers support sterile-load tracking for regulatory audit and patient-instrument linkage.

FDA
Class II (21 CFR 880.2800 sterilization indicator)
Latex
Latex-free
Sterility
Non-sterile (indicators are consumables used in sterilization)
Biocompatibility
ISO 10993 where applicable

Standards & Certifications

  • FDA 510(k) Cleared
  • ISO 11140-1 (chemical indicator classification)
  • ISO 11138 (biological indicators)
  • AAMI ST79 (steam sterilization and sterility assurance)

More from 3M

Global innovation in medical science

3M Health Care combines material science with clinical insight to produce category-defining products across wound care, infection prevention, and respiratory protection.

Frequently asked.

Answers to the questions clinical buyers and care teams ask most about this product category.

What's the difference between chemical and biological indicators?

Chemical indicators react to one or more sterilization parameters (time, temperature, pressure, steam presence) — they confirm the cycle ran, not that sterilization was achieved. Biological indicators contain resistant bacterial spores (G. stearothermophilus) that only die under true sterilization conditions — they confirm actual microbial kill.

How often do I need to run a biological indicator?

AAMI ST79 requires a BI at least weekly, in every implantable load, and after any major maintenance. Many facilities run BIs daily or with every load for extra safety margin.

What's a Class 5 integrating indicator?

Class 5 indicators react to all critical sterilization parameters (time, temperature, and steam quality) and closely correlate with BI performance. They allow some release decisions when combined with other quality measures.

Can sterilization pouches be reused?

No. Sterilization pouches are single-use. The sealing and barrier layers are compromised after one cycle, and reprocessing voids the sterility assurance level.

How long are sterile packs good for after processing?

Most modern guidance is event-related — packs stay sterile until the packaging is compromised (torn, wet, dropped). Time-dated shelf life (e.g., 30 days) may still apply per facility policy.